logo
Good price  online

products details

Home > Products >
Fire Alarm Flame Detector
>
DC24V UV Flame Detector with 120 Degree Detection Angle and ≤3 Seconds Response Time for Fire Alarm Systems

DC24V UV Flame Detector with 120 Degree Detection Angle and ≤3 Seconds Response Time for Fire Alarm Systems

Brand Name: XHA
Model Number: XHARS602
MOQ: 1PCS
Price: negotiable
Packaging Details: 8pcs/Carton
Payment Terms: T/T,Western Union
Detail Information
Place of Origin:
China
Certification:
CCC
Description:
The Server Understood The Request, But Is Refusing To Fulfill It.
Server:
Openresty
Supply Ability:
500pcs/month
Highlight:

DC24V UV Flame Detector

,

120 Degree Detection Angle UV Flame Detector

,

≤3 Seconds Response Time Fire Alarm Flame Detector

Product Description

DC24V High-Performance UV Fire Alarm Flame Detector For High-Risk Environments
 

DC24V UV Flame Detector with 120 Degree Detection Angle and ≤3 Seconds Response Time for Fire Alarm Systems 0
Introduction


 It utilizes ultraviolet (UV) light sensing technology to identify the unique UV radiation signature emitted by burning substances, providing fast and reliable fire detection capabilities.When the detector senses the presence of flames, it triggers the relay to signal an alarm condition to the control panel, which can then initiate appropriate emergency response procedures, such as activating notification appliances, releasing fire suppression systems, or notifying emergency services.

Specification
 
Operating Voltage Range: 12 to 28 VDC Volts
Standby Current: ≤10 mA @ 24 VDC
Alarm Current ≤30 mA @ 24 VDC
Spectrum: 180~290nm
Detection Angle: 120 degree
Respond time:≤3seconds
Detection Sensitivity: Grade I, 25m@flame (Container 33cmX33cm,Height 5cm with 2Kg ethanol )
Normal Status: LED blinking in 5 seconds interval
Alarm Status: LED lit steady



 DC24V UV Flame Detector with 120 Degree Detection Angle and ≤3 Seconds Response Time for Fire Alarm Systems 1
Installation
 
Terminal dispcription

Terminal 1: Relay Output -COM (ZONE+)
Terminal 2: Relay Output - NO/NC (ZONE-)
Terminal 3: DC Power -
Terminal 4: DC Power +
2. The detector can be connected with Security alarm panel as Figure3. Relay output signal can be changed from Normal Close (NC) to Normal Open (NO) by Jump JP1 on the PCB board.
3. The detector can be connected with conventional alarm panel as Figure 4. One 4.7K ohm resistor should be connected as End of Line (EOL) resistor at the last detector.
4. After the installation, power on the detector, use lighter or candle to test the detector within 3 meters.


Application in Conventional Fire Alarm system

DC24V UV Flame Detector with 120 Degree Detection Angle and ≤3 Seconds Response Time for Fire Alarm Systems 2DC24V UV Flame Detector with 120 Degree Detection Angle and ≤3 Seconds Response Time for Fire Alarm Systems 3
Product Range
Conventional Fire Alarm System
Addressable fire alarm system
Gas Extinguishing control system
Beam Detector
4 wire smoke detectors with relay output.
2 wire Conventional smoke and heat detectors
Explosion-proof flame detector for fire alarm system
Standalone smoke detectors and combustable gas detector

Service
1. OEM &ODM service.
2. Provide technical support and after-sale service.
3. 1 year warranty.
4. Normally 15 working days lead time.

5. Welcome sample order.

 




Good price  online

Products Details

Home > Products >
Fire Alarm Flame Detector
>
DC24V UV Flame Detector with 120 Degree Detection Angle and ≤3 Seconds Response Time for Fire Alarm Systems

DC24V UV Flame Detector with 120 Degree Detection Angle and ≤3 Seconds Response Time for Fire Alarm Systems

Brand Name: XHA
Model Number: XHARS602
MOQ: 1PCS
Price: negotiable
Packaging Details: 8pcs/Carton
Payment Terms: T/T,Western Union
Detail Information
Place of Origin:
China
Brand Name:
XHA
Certification:
CCC
Model Number:
XHARS602
Description:
The Server Understood The Request, But Is Refusing To Fulfill It.
Server:
Openresty
Minimum Order Quantity:
1PCS
Price:
negotiable
Packaging Details:
8pcs/Carton
Delivery Time:
3 Working days
Payment Terms:
T/T,Western Union
Supply Ability:
500pcs/month
Highlight:

DC24V UV Flame Detector

,

120 Degree Detection Angle UV Flame Detector

,

≤3 Seconds Response Time Fire Alarm Flame Detector

Product Description

DC24V High-Performance UV Fire Alarm Flame Detector For High-Risk Environments
 

DC24V UV Flame Detector with 120 Degree Detection Angle and ≤3 Seconds Response Time for Fire Alarm Systems 0
Introduction


 It utilizes ultraviolet (UV) light sensing technology to identify the unique UV radiation signature emitted by burning substances, providing fast and reliable fire detection capabilities.When the detector senses the presence of flames, it triggers the relay to signal an alarm condition to the control panel, which can then initiate appropriate emergency response procedures, such as activating notification appliances, releasing fire suppression systems, or notifying emergency services.

Specification
 
Operating Voltage Range: 12 to 28 VDC Volts
Standby Current: ≤10 mA @ 24 VDC
Alarm Current ≤30 mA @ 24 VDC
Spectrum: 180~290nm
Detection Angle: 120 degree
Respond time:≤3seconds
Detection Sensitivity: Grade I, 25m@flame (Container 33cmX33cm,Height 5cm with 2Kg ethanol )
Normal Status: LED blinking in 5 seconds interval
Alarm Status: LED lit steady



 DC24V UV Flame Detector with 120 Degree Detection Angle and ≤3 Seconds Response Time for Fire Alarm Systems 1
Installation
 
Terminal dispcription

Terminal 1: Relay Output -COM (ZONE+)
Terminal 2: Relay Output - NO/NC (ZONE-)
Terminal 3: DC Power -
Terminal 4: DC Power +
2. The detector can be connected with Security alarm panel as Figure3. Relay output signal can be changed from Normal Close (NC) to Normal Open (NO) by Jump JP1 on the PCB board.
3. The detector can be connected with conventional alarm panel as Figure 4. One 4.7K ohm resistor should be connected as End of Line (EOL) resistor at the last detector.
4. After the installation, power on the detector, use lighter or candle to test the detector within 3 meters.


Application in Conventional Fire Alarm system

DC24V UV Flame Detector with 120 Degree Detection Angle and ≤3 Seconds Response Time for Fire Alarm Systems 2DC24V UV Flame Detector with 120 Degree Detection Angle and ≤3 Seconds Response Time for Fire Alarm Systems 3
Product Range
Conventional Fire Alarm System
Addressable fire alarm system
Gas Extinguishing control system
Beam Detector
4 wire smoke detectors with relay output.
2 wire Conventional smoke and heat detectors
Explosion-proof flame detector for fire alarm system
Standalone smoke detectors and combustable gas detector

Service
1. OEM &ODM service.
2. Provide technical support and after-sale service.
3. 1 year warranty.
4. Normally 15 working days lead time.

5. Welcome sample order.