Product Name:
Heat Detector With Relay Output
Sound Pressure Level:
≥80db
Output:
Sound&light Alarm, Relay Output/NO NC Option
Rated Operational Voltage:
DC9~28V
Static Current:
≤200uA
Work Temperature:
-10°C~+50°C
Supply Ability:
10000PCS/Month
Highlight:

4-wire fire alarm detector

,

4-wire smoke detector with warranty

,

accurate fire detection alarm

Product Description

DC12/24V Power Cabinet/Machine Room 4-Wire Smoke Heat Detector With Relay Output No/Nc Option



Description 4-Wire Fire Alarm Detector for Accurate and Timely Fire Detection 0



Introduction

4-Wire heat alarm with relay output is common used for industrial control equipment, power cabinet, charging pile, alarm bell etc fire warning system. This smoke alarm has the characteristics of high sensitivity, stability and reliability, small power consumption and durability. Easy to install.


Parameters

 
Product Name heat detector with relay output Rated operational voltage DC9~28V
Sound pressure level ≥80db Static current ≤200uA
Alarm current ≤80mA Work temperature -10°C~+50°C
Output Sound&light alarm, relay output/NO NC option Humidity ≤95%.
activate temperature  62±2°C Contact capacity 1A/DC24V



Functions

1. Detection. 
Press detection button, it can fully check the alarm functions. And the alarm light  flashes quickly with a rapid sound.
2. Alarm. 
Under normal situation, the detector indicator will automatically flash every 4seconds. The detector automatically detects the temperature change of the surrounding environment. When the temperature rises to the setting of fire alarm, the detector alarms, the indicator light blinks rapidly, the buzzer buzzes rapidly, and the output action is maintained until the detector is powered off or the enviorment temperature return to normal status.

3. Output.
Passive contact output. Contact capacity 24V/1A, NC or NO two kinds of output.



Installation

First drill two mounting holes with a diameter of 5mm on the ceiling 43~ 62.5mm apart. Fix the alarm base with the plug and screw. Then connect the power line and output line.install the alarm to the base in the correct direction. Press down and tighten clockwise, finally turn on the power, it works.

Description 4-Wire Fire Alarm Detector for Accurate and Timely Fire Detection 1

Product range

Conventional Fire Alarm System
Addressable fire alarm system
Gas Extinguishing control system
Beam Detector
4 wire smoke detectors with relay output.
2 wire Conventional smoke and heat detectors
Explosion-proof flame detector for fire alarm system
Standalone smoke detectors and combustable gas detector



Service

1. OEM &ODM service.
2. Provide technical support and after-sale service.
3. 1 year warranty.
4. Normally 15 working days lead time.

5. Welcome sample order.


 


 




Good price  online

Products Details

Home > Products >
4 Wire Smoke Detector
>
Description 4-Wire Fire Alarm Detector for Accurate and Timely Fire Detection

Description 4-Wire Fire Alarm Detector for Accurate and Timely Fire Detection

Brand Name: XHA
Model Number: CA2005L
MOQ: 1PCS
Price: negotiable
Packaging Details: 100pcs/carton
Payment Terms: T/T,Western Union
Detail Information
Place of Origin:
China
Brand Name:
XHA
Certification:
CE
Model Number:
CA2005L
Product Name:
Heat Detector With Relay Output
Sound Pressure Level:
≥80db
Output:
Sound&light Alarm, Relay Output/NO NC Option
Rated Operational Voltage:
DC9~28V
Static Current:
≤200uA
Work Temperature:
-10°C~+50°C
Minimum Order Quantity:
1PCS
Price:
negotiable
Packaging Details:
100pcs/carton
Delivery Time:
3 Working days
Payment Terms:
T/T,Western Union
Supply Ability:
10000PCS/Month
Highlight:

4-wire fire alarm detector

,

4-wire smoke detector with warranty

,

accurate fire detection alarm

Product Description

DC12/24V Power Cabinet/Machine Room 4-Wire Smoke Heat Detector With Relay Output No/Nc Option



Description 4-Wire Fire Alarm Detector for Accurate and Timely Fire Detection 0



Introduction

4-Wire heat alarm with relay output is common used for industrial control equipment, power cabinet, charging pile, alarm bell etc fire warning system. This smoke alarm has the characteristics of high sensitivity, stability and reliability, small power consumption and durability. Easy to install.


Parameters

 
Product Name heat detector with relay output Rated operational voltage DC9~28V
Sound pressure level ≥80db Static current ≤200uA
Alarm current ≤80mA Work temperature -10°C~+50°C
Output Sound&light alarm, relay output/NO NC option Humidity ≤95%.
activate temperature  62±2°C Contact capacity 1A/DC24V



Functions

1. Detection. 
Press detection button, it can fully check the alarm functions. And the alarm light  flashes quickly with a rapid sound.
2. Alarm. 
Under normal situation, the detector indicator will automatically flash every 4seconds. The detector automatically detects the temperature change of the surrounding environment. When the temperature rises to the setting of fire alarm, the detector alarms, the indicator light blinks rapidly, the buzzer buzzes rapidly, and the output action is maintained until the detector is powered off or the enviorment temperature return to normal status.

3. Output.
Passive contact output. Contact capacity 24V/1A, NC or NO two kinds of output.



Installation

First drill two mounting holes with a diameter of 5mm on the ceiling 43~ 62.5mm apart. Fix the alarm base with the plug and screw. Then connect the power line and output line.install the alarm to the base in the correct direction. Press down and tighten clockwise, finally turn on the power, it works.

Description 4-Wire Fire Alarm Detector for Accurate and Timely Fire Detection 1

Product range

Conventional Fire Alarm System
Addressable fire alarm system
Gas Extinguishing control system
Beam Detector
4 wire smoke detectors with relay output.
2 wire Conventional smoke and heat detectors
Explosion-proof flame detector for fire alarm system
Standalone smoke detectors and combustable gas detector



Service

1. OEM &ODM service.
2. Provide technical support and after-sale service.
3. 1 year warranty.
4. Normally 15 working days lead time.

5. Welcome sample order.