Brand Name: XHA
Model Number: CA9006
MOQ: 1PCS
Price: negotiable
Packaging Details: 100pcs/carton
Payment Terms: T/T, Western Union
Detail Information
Place of Origin:
China
Certification:
CE
Working Voltage:
DC17V-DC33V
Wire Type:
Non-Polarity 2-Wired
Alarm Currrent:
≤2mA
Types Of Smoke Detectors:
Addressable Manual Call Point Button
Installation:
Wall Mounted
Customized:
Acceptable
Connected:
Loop Bus
Supply Ability:
100000PCS/Month
Highlight:

Explosion-Proof Addressable Manual Call Point

,

Intelligent Addressable Manual Call Point

Product Description

Addressable Manual Call Point For Intelligent Fire Safety Alarm System

 

 

 

Intelligent Fire Safety Alarm System Addressable Manual Call Point For Explosion-Proof Environments 0

Introduction
 

CA9006 manual call point adopts the latest digital loop protocol, electronic coding mode, including telephone jack. Installed in public places such as the wall of the building walkway, hotel floor near the service desk and other eye-catching places. After confirming the fire, press the operation board to send a fire alarm signal to the controller, and use the special key to reset the alarm state reported by the hand.


Parameters
 
Product name Manual Call Point (MCP) Type Addressable
Loop Bus wired 2-wire Non-polarized Monitor Current ≤300uA
Alarm Currrent ≤2mA Dimension Φ85*42 mm
Work voltage DC17V~DC33V Operating Environment Temperature -10°C~+50°C
 Humidity ≤95%.
Weight Weight:95g(with base) Certification CE



Main Functions

•Electrically addressed, can be modified by programmer.
•Re-settable (non-breaking glass) via special key
•Communication:2 wires,Non-polarized.

 

Connection between MCP

 

Intelligent Fire Safety Alarm System Addressable Manual Call Point For Explosion-Proof Environments 1

 

Connection Diagram of Fire Alarm System

 

Intelligent Fire Safety Alarm System Addressable Manual Call Point For Explosion-Proof Environments 2



Product range
 

Conventional Fire Alarm System
Addressable fire alarm system
Gas Extinguishing control system
Beam Detector
4 wire smoke detectors with relay output.
2 wire Conventional smoke and heat detectors
Explosion-proof flame detector for fire alarm system
Standalone smoke detectors and combustable gas detector



Service

1. OEM &ODM service.
2. Provide technical support and after-sale service.
3. 1 year warranty.
4. Normally 15 working days lead time.

5. Welcome sample order.
 

 
 

 

 

Good price  online

Products Details

Home > Products >
Addressable Fire Alarm System
>
Intelligent Fire Safety Alarm System Addressable Manual Call Point For Explosion-Proof Environments

Intelligent Fire Safety Alarm System Addressable Manual Call Point For Explosion-Proof Environments

Brand Name: XHA
Model Number: CA9006
MOQ: 1PCS
Price: negotiable
Packaging Details: 100pcs/carton
Payment Terms: T/T, Western Union
Detail Information
Place of Origin:
China
Brand Name:
XHA
Certification:
CE
Model Number:
CA9006
Working Voltage:
DC17V-DC33V
Wire Type:
Non-Polarity 2-Wired
Alarm Currrent:
≤2mA
Types Of Smoke Detectors:
Addressable Manual Call Point Button
Installation:
Wall Mounted
Customized:
Acceptable
Connected:
Loop Bus
Minimum Order Quantity:
1PCS
Price:
negotiable
Packaging Details:
100pcs/carton
Delivery Time:
3 Working days
Payment Terms:
T/T, Western Union
Supply Ability:
100000PCS/Month
Highlight:

Explosion-Proof Addressable Manual Call Point

,

Intelligent Addressable Manual Call Point

Product Description

Addressable Manual Call Point For Intelligent Fire Safety Alarm System

 

 

 

Intelligent Fire Safety Alarm System Addressable Manual Call Point For Explosion-Proof Environments 0

Introduction
 

CA9006 manual call point adopts the latest digital loop protocol, electronic coding mode, including telephone jack. Installed in public places such as the wall of the building walkway, hotel floor near the service desk and other eye-catching places. After confirming the fire, press the operation board to send a fire alarm signal to the controller, and use the special key to reset the alarm state reported by the hand.


Parameters
 
Product name Manual Call Point (MCP) Type Addressable
Loop Bus wired 2-wire Non-polarized Monitor Current ≤300uA
Alarm Currrent ≤2mA Dimension Φ85*42 mm
Work voltage DC17V~DC33V Operating Environment Temperature -10°C~+50°C
 Humidity ≤95%.
Weight Weight:95g(with base) Certification CE



Main Functions

•Electrically addressed, can be modified by programmer.
•Re-settable (non-breaking glass) via special key
•Communication:2 wires,Non-polarized.

 

Connection between MCP

 

Intelligent Fire Safety Alarm System Addressable Manual Call Point For Explosion-Proof Environments 1

 

Connection Diagram of Fire Alarm System

 

Intelligent Fire Safety Alarm System Addressable Manual Call Point For Explosion-Proof Environments 2



Product range
 

Conventional Fire Alarm System
Addressable fire alarm system
Gas Extinguishing control system
Beam Detector
4 wire smoke detectors with relay output.
2 wire Conventional smoke and heat detectors
Explosion-proof flame detector for fire alarm system
Standalone smoke detectors and combustable gas detector



Service

1. OEM &ODM service.
2. Provide technical support and after-sale service.
3. 1 year warranty.
4. Normally 15 working days lead time.