logo
Good price  online

products details

Home > Products >
Conventional Fire Alarm System
>
Conventional Fire Alarm System The Ultimate Solution for Fire Detection

Conventional Fire Alarm System The Ultimate Solution for Fire Detection

Brand Name: XHA
Model Number: XHA8015
MOQ: 1
Price: negotiable
Packaging Details: carton
Payment Terms: T/T, Western union
Detail Information
Place of Origin:
China
Certification:
CE
Detection Method:
Smoke Alarm
Power Supply:
DC9-28V
Sensitivity:
Adjustable
Type:
Conventional Fire Alarm System
Installation:
Ceiling Mount
Compatibility:
Compatible With Conventional Detectors
Number Of Zones:
Used For 2/4/8/16 Zone Fire Alarm System
Operating Temperature:
-10°C To 50°C
Supply Ability:
100000pcs/month
Highlight:

16 zone conventional fire alarm system

,

16 zone fire alarm system conventional

,

ceiling mount conventional fire alarm system

Product Description

Conventional Fire Alarm System The Ultimate Solution for Fire Detection 0

Product Description

 

This kind of smoke detector is crucial for commercial and residential buildings to ensure the safety of occupants and to meet regulatory requirements for fire safety systems.the detector can communicate using a two-wire system, which is common in fire alarm systems for transmitting both power and signal over the same wires.It uses a microcontroller unit (MCU) with sophisticated algorithms that can accurately detect smoke and distinguish it from other particles, reducing false alarms.

It adoped Advanced MCU Expert Algorithm Software, SMD circuit board design-satisfactory quality and reliability guaranteed ,which can be used for any brand conventional fire alarm controllers to realize smoke detection and early alarm monitoring functions.

 

Technical Parameters:

Type Conventional smoke alarm with remote LED function
Power Supply DC9-27V
Installation Ceiling Mount
Number Of Zones used for 2/4/8/16 zone fire alarm system
Wired 2 wire, Non-polarized
Operating Temperature -10°C To 50°C
Operating Humidity 10% To 95%
Alarm Output Sound/Light
 

Conventional Fire Alarm System The Ultimate Solution for Fire Detection 1

Conventional Fire Alarm System The Ultimate Solution for Fire Detection 2

 

Product Range

 

Conventional Fire Alarm System
Addressable fire alarm system
Gas Extinguishing control system
Beam Detector
4 wire smoke detectors with relay output.
2 wire Conventional smoke and heat detectors
Explosion-proof flame detector for fire alarm system
Standalone smoke detectors and combustable gas detector

 

 
 

 

 

Good price  online

Products Details

Home > Products >
Conventional Fire Alarm System
>
Conventional Fire Alarm System The Ultimate Solution for Fire Detection

Conventional Fire Alarm System The Ultimate Solution for Fire Detection

Brand Name: XHA
Model Number: XHA8015
MOQ: 1
Price: negotiable
Packaging Details: carton
Payment Terms: T/T, Western union
Detail Information
Place of Origin:
China
Brand Name:
XHA
Certification:
CE
Model Number:
XHA8015
Detection Method:
Smoke Alarm
Power Supply:
DC9-28V
Sensitivity:
Adjustable
Type:
Conventional Fire Alarm System
Installation:
Ceiling Mount
Compatibility:
Compatible With Conventional Detectors
Number Of Zones:
Used For 2/4/8/16 Zone Fire Alarm System
Operating Temperature:
-10°C To 50°C
Minimum Order Quantity:
1
Price:
negotiable
Packaging Details:
carton
Delivery Time:
3-7working days
Payment Terms:
T/T, Western union
Supply Ability:
100000pcs/month
Highlight:

16 zone conventional fire alarm system

,

16 zone fire alarm system conventional

,

ceiling mount conventional fire alarm system

Product Description

Conventional Fire Alarm System The Ultimate Solution for Fire Detection 0

Product Description

 

This kind of smoke detector is crucial for commercial and residential buildings to ensure the safety of occupants and to meet regulatory requirements for fire safety systems.the detector can communicate using a two-wire system, which is common in fire alarm systems for transmitting both power and signal over the same wires.It uses a microcontroller unit (MCU) with sophisticated algorithms that can accurately detect smoke and distinguish it from other particles, reducing false alarms.

It adoped Advanced MCU Expert Algorithm Software, SMD circuit board design-satisfactory quality and reliability guaranteed ,which can be used for any brand conventional fire alarm controllers to realize smoke detection and early alarm monitoring functions.

 

Technical Parameters:

Type Conventional smoke alarm with remote LED function
Power Supply DC9-27V
Installation Ceiling Mount
Number Of Zones used for 2/4/8/16 zone fire alarm system
Wired 2 wire, Non-polarized
Operating Temperature -10°C To 50°C
Operating Humidity 10% To 95%
Alarm Output Sound/Light
 

Conventional Fire Alarm System The Ultimate Solution for Fire Detection 1

Conventional Fire Alarm System The Ultimate Solution for Fire Detection 2

 

Product Range

 

Conventional Fire Alarm System
Addressable fire alarm system
Gas Extinguishing control system
Beam Detector
4 wire smoke detectors with relay output.
2 wire Conventional smoke and heat detectors
Explosion-proof flame detector for fire alarm system
Standalone smoke detectors and combustable gas detector