Non-Polarized 2-Wired Loop Bus for Easy Installation of Addressable Fire Alarm System

Non-Polarized 2-Wired Loop Bus for Easy Installation of Addressable Fire Alarm System

Brand Name: XHA
Model Number: CA200
MOQ: 1PCS
Price: negotiable
Packaging Details: 1PCS/Carton
Payment Terms: T/T, Western Union
Detail Information
Place of Origin:
China
Certification:
CE
LCD:
Colored, Touch Panel | Customized Request
Product Type:
Addressable Fire Alarm System
Number Of Detectors:
Max. 1524points
Wiring Mode:
Non-Polarity 2 Wired
Alarm Output:
Relay Output, Sounder Output, Strobe Output
Capacity:
254points/loop
Power Supply:
AC 90-240V, 50/60Hz
Communication Protocol:
RS485
Operating Temperature:
-10°C To 50°C
Humidity Range:
10% To 95% (non-condensing)
Supply Ability:
500pcs/month
Highlight:

rs485 addressable fire alarm system

,

254points addressable fire alarm system

,

rs485 addressable fire detection and alarm system

Product Description

Non-Polarized 2-Wired Loop Bus for Easy Installation of Addressable Fire Alarm System 0



Introduction

 

Addressable systems are commonly used in commercial, institutional, and industrial facilities where the ability to pinpoint alarm locations is important for rapid response and effective fire management.

 

 

 

This addressing capability allows the fire alarm control panel to precisely identify the location of an activated device during an alarm condition. Rather than just knowing that a fire alarm has been triggered somewhere in the building, the control panel can pinpoint the exact device that has been activated.

The core components of an addressable fire alarm system include:

Addressable Fire Alarm Control Panel - The main control unit that monitors and controls all the system devices.
Addressable Initiating Devices - Things like smoke detectors, heat detectors, and manual pull stations that have built-in microprocessors to communicate with the control panel.
Addressable Notification Appliances - Devices like sirens, strobes, and speakers that are also addressable and can be individually controlled.
Addressable Modules - Interfaces that allow the system to monitor and control external equipment like elevators, HVAC systems, and door locks.
The addressable devices communicate with the control panel using digital communication protocols like CLIP, MAPNET, or IDNET. This digital signaling allows for more advanced monitoring, testing, and diagnosis capabilities compared to older hardwired systems.

Addressable fire alarm systems are commonly used in commercial, institutional, and industrial facilities where the ability to quickly identify the precise location of a fire is critical for life safety and property protection. Their enhanced capabilities make them a more robust and flexible solution over traditional systems.

 


Parameters
 
Product Name Addressable Fire Alarm Control Panel Capacity  1-1524control points, maximum 6 loops
Capacity Maximum 6 loops Main power supply AC220V± 15%, 2.5A, 50HZ. 
Battery power supply DC 24V (2 sealed batteries: 2*12V*7Ah) Loop Bus wired Non-polarity 2 wired.
LCD Touch panel, Networkable, Colored LCD
 
 Operating Environment Temperature -10°C~+50°C
 Humidity ≤95%.
Dimentions  400mm×500mm×125mm.  Certification  CE



Main Functions

1. System self-test function. The system will test indicator light, LCD screen, sounder etc.
2. Inquiry function. Check model type zone number, device definition etc.
3. Event record. Record the fire alarm information and other operation record.
4. Data sampling.  Data analysis.
5. Setting function. Set the password, time, printer information.
6. Install and programming. Address coding, Login, Logical programming
7. Feedback function. Give real-time feedback information after starting the equipment.
8. Faulty alarm function. Automatically check the working status of main power supply, battery power supply, detectors , modules and report the detail fault information.


 



Product Range

Conventional Fire Alarm System
Addressable fire alarm system
Gas Extinguishing control system
Beam Detector
4 wire smoke detectors with relay output.
2 wire Conventional smoke and heat detectors
Explosion-proof flame detector for fire alarm system
Standalone smoke detectors and combustable gas detector



Service

1. OEM &ODM service.
2. Provide special technical support and after-sale service.
3. 1 year warranty.
4. Normally 15 working days lead time.

5. Welcome sample order.


 
Good price  online

Products Details

Home > Products >
Addressable Fire Alarm System
>
Non-Polarized 2-Wired Loop Bus for Easy Installation of Addressable Fire Alarm System

Non-Polarized 2-Wired Loop Bus for Easy Installation of Addressable Fire Alarm System

Brand Name: XHA
Model Number: CA200
MOQ: 1PCS
Price: negotiable
Packaging Details: 1PCS/Carton
Payment Terms: T/T, Western Union
Detail Information
Place of Origin:
China
Brand Name:
XHA
Certification:
CE
Model Number:
CA200
LCD:
Colored, Touch Panel | Customized Request
Product Type:
Addressable Fire Alarm System
Number Of Detectors:
Max. 1524points
Wiring Mode:
Non-Polarity 2 Wired
Alarm Output:
Relay Output, Sounder Output, Strobe Output
Capacity:
254points/loop
Power Supply:
AC 90-240V, 50/60Hz
Communication Protocol:
RS485
Operating Temperature:
-10°C To 50°C
Humidity Range:
10% To 95% (non-condensing)
Minimum Order Quantity:
1PCS
Price:
negotiable
Packaging Details:
1PCS/Carton
Delivery Time:
7 Working days
Payment Terms:
T/T, Western Union
Supply Ability:
500pcs/month
Highlight:

rs485 addressable fire alarm system

,

254points addressable fire alarm system

,

rs485 addressable fire detection and alarm system

Product Description

Non-Polarized 2-Wired Loop Bus for Easy Installation of Addressable Fire Alarm System 0



Introduction

 

Addressable systems are commonly used in commercial, institutional, and industrial facilities where the ability to pinpoint alarm locations is important for rapid response and effective fire management.

 

 

 

This addressing capability allows the fire alarm control panel to precisely identify the location of an activated device during an alarm condition. Rather than just knowing that a fire alarm has been triggered somewhere in the building, the control panel can pinpoint the exact device that has been activated.

The core components of an addressable fire alarm system include:

Addressable Fire Alarm Control Panel - The main control unit that monitors and controls all the system devices.
Addressable Initiating Devices - Things like smoke detectors, heat detectors, and manual pull stations that have built-in microprocessors to communicate with the control panel.
Addressable Notification Appliances - Devices like sirens, strobes, and speakers that are also addressable and can be individually controlled.
Addressable Modules - Interfaces that allow the system to monitor and control external equipment like elevators, HVAC systems, and door locks.
The addressable devices communicate with the control panel using digital communication protocols like CLIP, MAPNET, or IDNET. This digital signaling allows for more advanced monitoring, testing, and diagnosis capabilities compared to older hardwired systems.

Addressable fire alarm systems are commonly used in commercial, institutional, and industrial facilities where the ability to quickly identify the precise location of a fire is critical for life safety and property protection. Their enhanced capabilities make them a more robust and flexible solution over traditional systems.

 


Parameters
 
Product Name Addressable Fire Alarm Control Panel Capacity  1-1524control points, maximum 6 loops
Capacity Maximum 6 loops Main power supply AC220V± 15%, 2.5A, 50HZ. 
Battery power supply DC 24V (2 sealed batteries: 2*12V*7Ah) Loop Bus wired Non-polarity 2 wired.
LCD Touch panel, Networkable, Colored LCD
 
 Operating Environment Temperature -10°C~+50°C
 Humidity ≤95%.
Dimentions  400mm×500mm×125mm.  Certification  CE



Main Functions

1. System self-test function. The system will test indicator light, LCD screen, sounder etc.
2. Inquiry function. Check model type zone number, device definition etc.
3. Event record. Record the fire alarm information and other operation record.
4. Data sampling.  Data analysis.
5. Setting function. Set the password, time, printer information.
6. Install and programming. Address coding, Login, Logical programming
7. Feedback function. Give real-time feedback information after starting the equipment.
8. Faulty alarm function. Automatically check the working status of main power supply, battery power supply, detectors , modules and report the detail fault information.


 



Product Range

Conventional Fire Alarm System
Addressable fire alarm system
Gas Extinguishing control system
Beam Detector
4 wire smoke detectors with relay output.
2 wire Conventional smoke and heat detectors
Explosion-proof flame detector for fire alarm system
Standalone smoke detectors and combustable gas detector



Service

1. OEM &ODM service.
2. Provide special technical support and after-sale service.
3. 1 year warranty.
4. Normally 15 working days lead time.

5. Welcome sample order.