logo
Good price  online

products details

Home > Products >
Fire Alarm Flame Detector
>
Industrial Fire Alarm Ultroviolet UV Flame Detector With IP66 / IP65 Protection

Industrial Fire Alarm Ultroviolet UV Flame Detector With IP66 / IP65 Protection

Brand Name: XHA
Model Number: YJLH101EX
MOQ: 1PCS
Price: negotiable
Packaging Details: 10pcs/Carton
Payment Terms: T/T, Western Union
Detail Information
Place of Origin:
China
Certification:
CCC
Power Supply:
24V DC
Detection Method:
Ultroviolet UV Sensor
Response Time:
Less Than 5 Seconds
Alarm Output:
Relay Output
Detection Range:
1-40 Meters
Humidity Range:
10% To 95% Non-condensing
Operating Temperature:
-10°C To 55°C
Installation:
Ceiling/Wall Mounted
Supply Ability:
1000pcs/month
Highlight:

Industrial UV Flame Detector

,

Ultroviolet UV Flame Detector

,

Ultraviolet Flame Detector Fire Alarm

Product Description

Industrial Fire Alarm Ultroviolet UV Flame Detector With IP66/IP65 Protection For Fire Safety Alarm System

Industrial Fire Alarm Ultroviolet UV Flame Detector With IP66 / IP65 Protection 0

Introduction
 

xplosion-proof UV flame detectors are specialized sensors designed to detect the presence of flames in hazardous, potentially explosive environments. These detectors rely on the unique ultraviolet (UV) light signature emitted by combustion to identify the presence of a fire.

 

Explosion-proof UV flame detectors are widely used in industries with potentially explosive environments, such as oil and gas refineries, chemical plants, and fuel storage facilities. By providing early and accurate fire detection, these specialized sensors play a crucial role in safeguarding personnel, equipment, and operations in hazardous areas


 


Specifications

 

 

 

Working voltage 18V-32VDC
Interface 4”(Φ20mm) explosion-proof hose
Infrared Flame Detector Detection Angle 120 degree
Level of protection IP66/IP65
Explosion Proof Level Ex d lIC T6 Gb. Ex tD A21 IP66/IP67 T80℃
Alarm Status ≤40mA/24VDC
Fire response time ≤5S
Sensitivity 1m-40m can respond(0.1 m-1.3m)
Working environment humidity ≤95%RH, no condensation


 

Instruction

 

Industrial Fire Alarm Ultroviolet UV Flame Detector With IP66 / IP65 Protection 1


The green work indicator is steady on at the normal situation.
when the fire is found, The red alarm indicator is steady on. At the same time, the fire alarm relay is closed and the yellow/white lines are conductive, output the fire alarm signal.
The detector is a non-coding detector, which needs to connect the interface module when it is connected to the bus system.

 

Wiring Instruction

 

Industrial Fire Alarm Ultroviolet UV Flame Detector With IP66 / IP65 Protection 2


Red/black: 24V power line
Yellow/white:Alarm relay ouput, it is closed, normally open.
Blue/green:Fault relay output, it’s open, normally closed.
Maintenance:
In order to keep in good work situation, it need arrange test to the flame detector every 3 months at least. Once the detector is damaged or not working properly, need to repaire or replace accordingly.

 

Industrial Fire Alarm Ultroviolet UV Flame Detector With IP66 / IP65 Protection 3


Product range

Conventional Fire Alarm System
Addressable fire alarm system
Gas Extinguishing control system
Beam Detector
4 wire smoke detectors with relay output.
2 wire Conventional smoke and heat detectors
Explosion-proof flame detector for fire alarm system
Standalone smoke detectors and combustable gas detector



Service

1. OEM &ODM service.
2. Provide technical support and after-sale service.
3. 1 year warranty.
4. Normally 10 working days lead time.

5. Welcome sample order.

 

Good price  online

Products Details

Home > Products >
Fire Alarm Flame Detector
>
Industrial Fire Alarm Ultroviolet UV Flame Detector With IP66 / IP65 Protection

Industrial Fire Alarm Ultroviolet UV Flame Detector With IP66 / IP65 Protection

Brand Name: XHA
Model Number: YJLH101EX
MOQ: 1PCS
Price: negotiable
Packaging Details: 10pcs/Carton
Payment Terms: T/T, Western Union
Detail Information
Place of Origin:
China
Brand Name:
XHA
Certification:
CCC
Model Number:
YJLH101EX
Power Supply:
24V DC
Detection Method:
Ultroviolet UV Sensor
Response Time:
Less Than 5 Seconds
Alarm Output:
Relay Output
Detection Range:
1-40 Meters
Humidity Range:
10% To 95% Non-condensing
Operating Temperature:
-10°C To 55°C
Installation:
Ceiling/Wall Mounted
Minimum Order Quantity:
1PCS
Price:
negotiable
Packaging Details:
10pcs/Carton
Delivery Time:
3 Working days
Payment Terms:
T/T, Western Union
Supply Ability:
1000pcs/month
Highlight:

Industrial UV Flame Detector

,

Ultroviolet UV Flame Detector

,

Ultraviolet Flame Detector Fire Alarm

Product Description

Industrial Fire Alarm Ultroviolet UV Flame Detector With IP66/IP65 Protection For Fire Safety Alarm System

Industrial Fire Alarm Ultroviolet UV Flame Detector With IP66 / IP65 Protection 0

Introduction
 

xplosion-proof UV flame detectors are specialized sensors designed to detect the presence of flames in hazardous, potentially explosive environments. These detectors rely on the unique ultraviolet (UV) light signature emitted by combustion to identify the presence of a fire.

 

Explosion-proof UV flame detectors are widely used in industries with potentially explosive environments, such as oil and gas refineries, chemical plants, and fuel storage facilities. By providing early and accurate fire detection, these specialized sensors play a crucial role in safeguarding personnel, equipment, and operations in hazardous areas


 


Specifications

 

 

 

Working voltage 18V-32VDC
Interface 4”(Φ20mm) explosion-proof hose
Infrared Flame Detector Detection Angle 120 degree
Level of protection IP66/IP65
Explosion Proof Level Ex d lIC T6 Gb. Ex tD A21 IP66/IP67 T80℃
Alarm Status ≤40mA/24VDC
Fire response time ≤5S
Sensitivity 1m-40m can respond(0.1 m-1.3m)
Working environment humidity ≤95%RH, no condensation


 

Instruction

 

Industrial Fire Alarm Ultroviolet UV Flame Detector With IP66 / IP65 Protection 1


The green work indicator is steady on at the normal situation.
when the fire is found, The red alarm indicator is steady on. At the same time, the fire alarm relay is closed and the yellow/white lines are conductive, output the fire alarm signal.
The detector is a non-coding detector, which needs to connect the interface module when it is connected to the bus system.

 

Wiring Instruction

 

Industrial Fire Alarm Ultroviolet UV Flame Detector With IP66 / IP65 Protection 2


Red/black: 24V power line
Yellow/white:Alarm relay ouput, it is closed, normally open.
Blue/green:Fault relay output, it’s open, normally closed.
Maintenance:
In order to keep in good work situation, it need arrange test to the flame detector every 3 months at least. Once the detector is damaged or not working properly, need to repaire or replace accordingly.

 

Industrial Fire Alarm Ultroviolet UV Flame Detector With IP66 / IP65 Protection 3


Product range

Conventional Fire Alarm System
Addressable fire alarm system
Gas Extinguishing control system
Beam Detector
4 wire smoke detectors with relay output.
2 wire Conventional smoke and heat detectors
Explosion-proof flame detector for fire alarm system
Standalone smoke detectors and combustable gas detector



Service

1. OEM &ODM service.
2. Provide technical support and after-sale service.
3. 1 year warranty.
4. Normally 10 working days lead time.

5. Welcome sample order.