Brand Name: XHA
Model Number: XHARS602
MOQ: 1PCS
Price: negotiable
Packaging Details: 360*250*460mm/Carton
Payment Terms: T/T, Western Union
Detail Information
Place of Origin:
China
Certification:
CCC
Type:
Ultroviolet Flame Detector
Operating Voltage Range:
12 To 28 VDC Volts
Spectrum:
180~290nm
Relay Contact Load:
1A@DC24V
Alarm Output:
Relay Output, Normally Open/closed Optional
Detection Sensitivity:
Level 1 25m
Detection Angle:
120degree
Response Time:
≤3 Seconds
Installation:
Ceiling/Wall Mounted
Material:
ABS Plastic
Supply Ability:
1000PCS/Month
Highlight:

High Standard Fire Alarm Flame Detector

,

Fire Alarm Flame Detector 12VDC

,

Fire Alarm Flame Detector 28VDC

Product Description

High-Standard Fire Alarm Flame Detector With 12-28 VDC Operating Range

 

High Standard Fire Alarm Flame Detector 12VDC-28VDC Ceiling / Wall Mounted 0


Introduction

 

The DC24V Ultraviolet Flame Detector is a specialized sensor designed to quickly detect the presence of flames in high-risk environments. It utilizes ultraviolet (UV) light sensing technology to identify the unique UV radiation signature emitted by burning substances, providing fast and reliable fire detection capabilities.


Specification
 
Operating Voltage Range: 12 to 28 VDC Volts
Standby Current: ≤10 mA @ 24 VDC
Alarm Current ≤30 mA @ 24 VDC
Spectrum: 180~290nm
Detection Angle: 120 degree
Detection Sensitivity: Grade I, 25m@flame (Container 33cmX33cm,Height 5cm with 2Kg ethanol )
Relay Contact Load: 1A@DC24V
Normal Status: LED blinking in 5 seconds interval
Alarm Status: LED lit steady
Operating Humidity Range: 10% to 93% Relative Humidity, Non-condensing
Operating Temperature Range: -20°C to 55°C
 

 Ultroviolet Flame Detector with Relay Output for Fire Alarm System

Installation
 
NOTE: All wiring must conform to applicable local codes, ordinances, and regulations. Mounting Indoor Wall or Ceiling Products.
1. Attach mounting base to ceiling or wall.
2. Connect field wiring to terminals:
Terminal 1: Relay Output -COM (ZONE+)
Terminal 2: Relay Output - NO/NC (ZONE-)
Terminal 3: DC Power -
Terminal 4: DC Power +
3. To attach product to mounting base.
4. Secure product by tightening the two mounting screws in the front of the product housing.
5. The detector can be connected with Security alarm panel as Figure3. Relay output signal can be changed from Normal Close (NC) to Normal Open (NO) by Jump JP1 on the PCB board.
6. The detector can be connected with conventional alarm panel as Figure 4. One 4.7K ohm resistor should be connected as End of Line (EOL) resistor at the last detector.
7. After the installation, power on the detector, use lighter or candle to test the detector within 3 meters.

WARNIING:
Not to install flame detector near the below subjects:
1. Halogen lamp, Electric discharge lamp, ultraviolet ray lamp.
2. Welding spark, Electric spark
3. Heavy current magnetic field, thunder discharge.
4. Direct sunlight.
5.Ultra violet radiation subjects
The UV flame detector can not detect the following:
1. The flame behind the glass or transparent resin.
2. Lighted cigarette.
3. Burning charcoal and coal cakes.
4. Burning material without flame.

Application in Conventional Fire Alarm system

Ultroviolet Flame Detector with Relay Output for Fire Alarm SystemUltroviolet Flame Detector with Relay Output for Fire Alarm System

Product Range

Conventional Fire Alarm System
Addressable fire alarm system
Gas Extinguishing control system
Beam Detector
4 wire smoke detectors with relay output.
2 wire Conventional smoke and heat detectors
Explosion-proof flame detector for fire alarm system
Standalone smoke detectors and combustable gas detector




Service

1. OEM &ODM service.
2. Provide technical support and after-sale service.
3. 1 year warranty.
4. Normally 15 working days lead time.

5. Welcome sample order.



 
Good price  online

Products Details

Home > Products >
Fire Alarm Flame Detector
>
High Standard Fire Alarm Flame Detector 12VDC-28VDC Ceiling / Wall Mounted

High Standard Fire Alarm Flame Detector 12VDC-28VDC Ceiling / Wall Mounted

Brand Name: XHA
Model Number: XHARS602
MOQ: 1PCS
Price: negotiable
Packaging Details: 360*250*460mm/Carton
Payment Terms: T/T, Western Union
Detail Information
Place of Origin:
China
Brand Name:
XHA
Certification:
CCC
Model Number:
XHARS602
Type:
Ultroviolet Flame Detector
Operating Voltage Range:
12 To 28 VDC Volts
Spectrum:
180~290nm
Relay Contact Load:
1A@DC24V
Alarm Output:
Relay Output, Normally Open/closed Optional
Detection Sensitivity:
Level 1 25m
Detection Angle:
120degree
Response Time:
≤3 Seconds
Installation:
Ceiling/Wall Mounted
Material:
ABS Plastic
Minimum Order Quantity:
1PCS
Price:
negotiable
Packaging Details:
360*250*460mm/Carton
Delivery Time:
7 Working days
Payment Terms:
T/T, Western Union
Supply Ability:
1000PCS/Month
Highlight:

High Standard Fire Alarm Flame Detector

,

Fire Alarm Flame Detector 12VDC

,

Fire Alarm Flame Detector 28VDC

Product Description

High-Standard Fire Alarm Flame Detector With 12-28 VDC Operating Range

 

High Standard Fire Alarm Flame Detector 12VDC-28VDC Ceiling / Wall Mounted 0


Introduction

 

The DC24V Ultraviolet Flame Detector is a specialized sensor designed to quickly detect the presence of flames in high-risk environments. It utilizes ultraviolet (UV) light sensing technology to identify the unique UV radiation signature emitted by burning substances, providing fast and reliable fire detection capabilities.


Specification
 
Operating Voltage Range: 12 to 28 VDC Volts
Standby Current: ≤10 mA @ 24 VDC
Alarm Current ≤30 mA @ 24 VDC
Spectrum: 180~290nm
Detection Angle: 120 degree
Detection Sensitivity: Grade I, 25m@flame (Container 33cmX33cm,Height 5cm with 2Kg ethanol )
Relay Contact Load: 1A@DC24V
Normal Status: LED blinking in 5 seconds interval
Alarm Status: LED lit steady
Operating Humidity Range: 10% to 93% Relative Humidity, Non-condensing
Operating Temperature Range: -20°C to 55°C
 

 Ultroviolet Flame Detector with Relay Output for Fire Alarm System

Installation
 
NOTE: All wiring must conform to applicable local codes, ordinances, and regulations. Mounting Indoor Wall or Ceiling Products.
1. Attach mounting base to ceiling or wall.
2. Connect field wiring to terminals:
Terminal 1: Relay Output -COM (ZONE+)
Terminal 2: Relay Output - NO/NC (ZONE-)
Terminal 3: DC Power -
Terminal 4: DC Power +
3. To attach product to mounting base.
4. Secure product by tightening the two mounting screws in the front of the product housing.
5. The detector can be connected with Security alarm panel as Figure3. Relay output signal can be changed from Normal Close (NC) to Normal Open (NO) by Jump JP1 on the PCB board.
6. The detector can be connected with conventional alarm panel as Figure 4. One 4.7K ohm resistor should be connected as End of Line (EOL) resistor at the last detector.
7. After the installation, power on the detector, use lighter or candle to test the detector within 3 meters.

WARNIING:
Not to install flame detector near the below subjects:
1. Halogen lamp, Electric discharge lamp, ultraviolet ray lamp.
2. Welding spark, Electric spark
3. Heavy current magnetic field, thunder discharge.
4. Direct sunlight.
5.Ultra violet radiation subjects
The UV flame detector can not detect the following:
1. The flame behind the glass or transparent resin.
2. Lighted cigarette.
3. Burning charcoal and coal cakes.
4. Burning material without flame.

Application in Conventional Fire Alarm system

Ultroviolet Flame Detector with Relay Output for Fire Alarm SystemUltroviolet Flame Detector with Relay Output for Fire Alarm System

Product Range

Conventional Fire Alarm System
Addressable fire alarm system
Gas Extinguishing control system
Beam Detector
4 wire smoke detectors with relay output.
2 wire Conventional smoke and heat detectors
Explosion-proof flame detector for fire alarm system
Standalone smoke detectors and combustable gas detector




Service

1. OEM &ODM service.
2. Provide technical support and after-sale service.
3. 1 year warranty.
4. Normally 15 working days lead time.

5. Welcome sample order.