| Brand Name: | XHA |
| Model Number: | XHA8032 |
| MOQ: | 1 |
| Price: | negotiable |
| Packaging Details: | 100pcs/carton |
| Payment Terms: | T/T, Western Union |
Restorable Conventional Manual Alarm Call Point For Conventional Fire Alarm System
![]()
Introduction
Manual call points are devices installed on walls within buildings, typically at eye level and in prominent locations such as near exits, in corridors, and adjacent to stairwells.
A manual call point (MCP) is an alarm in a box with a button or level that you must manually push to trigger it. It has a protective glass or plastic casing that you must break to trigger it.
Parameters
| Product Name | Restorable Call Point | Rated operational voltage | 9 to 33VDC Volts Non-polarized |
| Relay contact rating | 1A/30VDC | Work temperature | -10°C~+50°C |
| Certification | CE | Humidity | ≤95%. |
| Size | 86*89*37mm | Weight | 125 g |
Installation
The call point has one 470ohm resistor is used on the pcb board between Zone+ and Zone- (Pin 1/2)or one relay contact(NO,COM)(pin 3/4) output when the button is pressed.
TO RESET
The call point can be reset by a key from alarm return to normal status
![]()
Product range
Conventional Fire Alarm System
Addressable fire alarm system
Gas Extinguishing control system
Beam Detector
4 wire smoke detectors with relay output.
2 wire Conventional smoke and heat detectors
Explosion-proof flame detector for fire alarm system
Standalone smoke detectors and combustable gas detector
Service
1. OEM &ODM service.
2. Provide technical support and after-sale service.
3. 1 year warranty.
4. Normally 15 working days lead time.
5. Welcome sample order.
| Brand Name: | XHA |
| Model Number: | XHA8032 |
| MOQ: | 1 |
| Price: | negotiable |
| Packaging Details: | 100pcs/carton |
| Payment Terms: | T/T, Western Union |
Restorable Conventional Manual Alarm Call Point For Conventional Fire Alarm System
![]()
Introduction
Manual call points are devices installed on walls within buildings, typically at eye level and in prominent locations such as near exits, in corridors, and adjacent to stairwells.
A manual call point (MCP) is an alarm in a box with a button or level that you must manually push to trigger it. It has a protective glass or plastic casing that you must break to trigger it.
Parameters
| Product Name | Restorable Call Point | Rated operational voltage | 9 to 33VDC Volts Non-polarized |
| Relay contact rating | 1A/30VDC | Work temperature | -10°C~+50°C |
| Certification | CE | Humidity | ≤95%. |
| Size | 86*89*37mm | Weight | 125 g |
Installation
The call point has one 470ohm resistor is used on the pcb board between Zone+ and Zone- (Pin 1/2)or one relay contact(NO,COM)(pin 3/4) output when the button is pressed.
TO RESET
The call point can be reset by a key from alarm return to normal status
![]()
Product range
Conventional Fire Alarm System
Addressable fire alarm system
Gas Extinguishing control system
Beam Detector
4 wire smoke detectors with relay output.
2 wire Conventional smoke and heat detectors
Explosion-proof flame detector for fire alarm system
Standalone smoke detectors and combustable gas detector
Service
1. OEM &ODM service.
2. Provide technical support and after-sale service.
3. 1 year warranty.
4. Normally 15 working days lead time.