Restorable Conventional Manual Alarm Call Point For Conventional Fire Alarm System
Introduction
Manual call points are devices installed on walls within buildings, typically at eye level and in prominent locations such as near exits, in corridors, and adjacent to stairwells.
A manual call point (MCP) is an alarm in a box with a button or level that you must manually push to trigger it. It has a protective glass or plastic casing that you must break to trigger it.
Parameters
Product Name | Restorable Call Point | Rated operational voltage | 9 to 33VDC Volts Non-polarized |
Relay contact rating | 1A/30VDC | Work temperature | -10°C~+50°C |
Certification | CE | Humidity | ≤95%. |
Size | 86*89*37mm | Weight | 125 g |
Installation
The call point has one 470ohm resistor is used on the pcb board between Zone+ and Zone- (Pin 1/2)or one relay contact(NO,COM)(pin 3/4) output when the button is pressed.
TO RESET
The call point can be reset by a key from alarm return to normal status
Product range
Conventional Fire Alarm System
Addressable fire alarm system
Gas Extinguishing control system
Beam Detector
4 wire smoke detectors with relay output.
2 wire Conventional smoke and heat detectors
Explosion-proof flame detector for fire alarm system
Standalone smoke detectors and combustable gas detector
Service
1. OEM &ODM service.
2. Provide technical support and after-sale service.
3. 1 year warranty.
4. Normally 15 working days lead time.
5. Welcome sample order.
Brand Name: | XHA |
Model Number: | XHA8032 |
MOQ: | 1 |
Price: | negotiable |
Packaging Details: | 100pcs/carton |
Payment Terms: | T/T, Western Union |
Restorable Conventional Manual Alarm Call Point For Conventional Fire Alarm System
Introduction
Manual call points are devices installed on walls within buildings, typically at eye level and in prominent locations such as near exits, in corridors, and adjacent to stairwells.
A manual call point (MCP) is an alarm in a box with a button or level that you must manually push to trigger it. It has a protective glass or plastic casing that you must break to trigger it.
Parameters
Product Name | Restorable Call Point | Rated operational voltage | 9 to 33VDC Volts Non-polarized |
Relay contact rating | 1A/30VDC | Work temperature | -10°C~+50°C |
Certification | CE | Humidity | ≤95%. |
Size | 86*89*37mm | Weight | 125 g |
Installation
The call point has one 470ohm resistor is used on the pcb board between Zone+ and Zone- (Pin 1/2)or one relay contact(NO,COM)(pin 3/4) output when the button is pressed.
TO RESET
The call point can be reset by a key from alarm return to normal status
Product range
Conventional Fire Alarm System
Addressable fire alarm system
Gas Extinguishing control system
Beam Detector
4 wire smoke detectors with relay output.
2 wire Conventional smoke and heat detectors
Explosion-proof flame detector for fire alarm system
Standalone smoke detectors and combustable gas detector
Service
1. OEM &ODM service.
2. Provide technical support and after-sale service.
3. 1 year warranty.
4. Normally 15 working days lead time.
5. Welcome sample order.