logo
Good price  online

products details

Home > Products >
Conventional Fire Alarm System
>
2 Zone Conventional Fire Alarm Panel Wall Mounted For Fire Fighting System

2 Zone Conventional Fire Alarm Panel Wall Mounted For Fire Fighting System

Brand Name: XHA
Model Number: XHA1002
MOQ: 4PCS
Packaging Details: 465*405*285mm
Payment Terms: T/T, Western Union
Detail Information
Place of Origin:
China
Certification:
CE
Connected:
2/4/8/16 Zone
Installation:
Wall Mounted
Communication:
RS485
Trademark:
XHA1002
Origin:
China
HS Code:
8531100000
Supply Ability:
1000/Month
Type:
Conventional Fire Alarm Controller
Types Of Smoke Detectors:
Photoelectric Smoke Style
Customization:
Available | Customized Request
Highlight:

2 Zone Conventional Fire Alarm Panel

,

Conventional Fire Alarm Panel 2 Zone

,

Conventional Fire Alarm Panel Wall Mounted

Product Description

Conventional Fire Alarm Panel 2 Zone For Fire Fighting System

 

Conventional 4/8/16 Zone Fire Alarm Control Panel for Automatic Fire Fighting System

Introduction

 
The fire alarm control panels (2 Zone,4 Zones, 8 Zones, and 16 Zones) provide all of the sophisticated features required of a
leading edge conventional fire alarm system along with the simple operation and efficient installation methods
demanded by both installers and building users.
The panel can be flush or surface mounted and the generously sized metal back box allows ample space for rear or top
cable entries.
A comprehensive range of auxiliary devices is available to operate with the fire control panels including optical,
ionization, photoelectric, photoelectric-thermal and heat detectors.
Each of the system components has been specifically designed to operate as part of the system. This provides
assurance that the control panel, smoke detectors, interface devices and the ancillary components are all fully
compatible with one another and that the full range of system functionality is supported by each device.
This series of panels are basically the same in application and operation, their differences are shown in Table 1. PANEL
will be described as the example in the following sections.



Product Features

4,8,16 Class B Initiating Device Circuits (lDCs).
. All zones accept conventional detectors and any normally open contact device.
. Four Class B Notification Appliance Circuits (NACs).
. One Form-A Alarm Relay.
. One Form-A Fault Relay.
. One Form-A Supervisory Relay
. 3.0 amps ofsystem power.
. Max 30 conventional detectors in one zone.
. Auto/Manual mode setting enable.
. Each Zone can be disabled.
. Sound output can be disabled.
. Manual active sound output enabled.
. Able to report short and broken circuit
of detection zones.
. Designed with standby batteries and space provision for 1 sealed lead- acid batteries
Evacuate,Testing and disable functions.
. Remote reset and silence alarm functions
. Can conneet max 32 repeater panels by RS485 communication port
. Dimensions :14.57"(37 cm) long X 17.32"(44 cm) high X 3.94"(10cm)
. Weight: 6.6kg (without battery)

 

Specification
 
Primary AC 120VAC 50/60 Hz Power supply rating
240VAC 50/60 Hz
Power supply rating 2 Amps @ 24VDC
Maximum Battery Charging Current 0.98 Amps @ 26VDC
Initiating Device Circuits 2 Zones Alarm Zone 2
Normal Initiating Operating Voltage 23VDC, Maximum 26VDC, regulated
Normal Quiescent Current (normal status) <50mA
Alarm Current (not include the others) <150 mA
Short Circuit Initiating Current (per zone) 35mA Maximum
Maximum Initiating Resistance (per zone) 10 ohms
Initiating End-of-Line Resistor 4K7 ohms, 1/2W 5%
Standby Detector Current (per zone) 4mA maximum
Maximum Detector Count (per zone) 30 detectors
Initiating Cabling Type 18AWG Twisted Shielded pair (14 – 18 AWG)
Detector Base Impedance 430 ohms
Notification Appliance Circuits 1 NACs, Special Application
Maximum NAC Current Rating 1 Amp maximum per circuit
NAC Operating Voltage 26VDC Nominal, 30VDC Maximum
NAC End-of-line Resistor 1N4007 Diode
FAULT Relay rating 2A & 30VAC, resistive
Alarm( Auxiliary ) Relay rating 2A & 30VAC, resistive
Master alarm panel Digital & LED display
Slave alarm panel LED display only


Product range

Conventional Fire Alarm System
Addressable fire alarm system
Gas Extinguishing control system
Beam Detector
Standalone smoke detectors and combustable gas detector
4 wire smoke detectors with relay output.
2 wire Conventional smoke and heat detectors
Explosion-proof flame detector for fire alarm system




Service


1. OEM &ODM service.
2. Provide technical support and after-sale service.
3. 1 year warranty.
4. Normally 15 working days lead time.

5. Welcome sample order.


 
Good price  online

Products Details

Home > Products >
Conventional Fire Alarm System
>
2 Zone Conventional Fire Alarm Panel Wall Mounted For Fire Fighting System

2 Zone Conventional Fire Alarm Panel Wall Mounted For Fire Fighting System

Brand Name: XHA
Model Number: XHA1002
MOQ: 4PCS
Packaging Details: 465*405*285mm
Payment Terms: T/T, Western Union
Detail Information
Place of Origin:
China
Brand Name:
XHA
Certification:
CE
Model Number:
XHA1002
Connected:
2/4/8/16 Zone
Installation:
Wall Mounted
Communication:
RS485
Trademark:
XHA1002
Origin:
China
HS Code:
8531100000
Supply Ability:
1000/Month
Type:
Conventional Fire Alarm Controller
Types Of Smoke Detectors:
Photoelectric Smoke Style
Customization:
Available | Customized Request
Minimum Order Quantity:
4PCS
Packaging Details:
465*405*285mm
Delivery Time:
3 Working days
Payment Terms:
T/T, Western Union
Highlight:

2 Zone Conventional Fire Alarm Panel

,

Conventional Fire Alarm Panel 2 Zone

,

Conventional Fire Alarm Panel Wall Mounted

Product Description

Conventional Fire Alarm Panel 2 Zone For Fire Fighting System

 

Conventional 4/8/16 Zone Fire Alarm Control Panel for Automatic Fire Fighting System

Introduction

 
The fire alarm control panels (2 Zone,4 Zones, 8 Zones, and 16 Zones) provide all of the sophisticated features required of a
leading edge conventional fire alarm system along with the simple operation and efficient installation methods
demanded by both installers and building users.
The panel can be flush or surface mounted and the generously sized metal back box allows ample space for rear or top
cable entries.
A comprehensive range of auxiliary devices is available to operate with the fire control panels including optical,
ionization, photoelectric, photoelectric-thermal and heat detectors.
Each of the system components has been specifically designed to operate as part of the system. This provides
assurance that the control panel, smoke detectors, interface devices and the ancillary components are all fully
compatible with one another and that the full range of system functionality is supported by each device.
This series of panels are basically the same in application and operation, their differences are shown in Table 1. PANEL
will be described as the example in the following sections.



Product Features

4,8,16 Class B Initiating Device Circuits (lDCs).
. All zones accept conventional detectors and any normally open contact device.
. Four Class B Notification Appliance Circuits (NACs).
. One Form-A Alarm Relay.
. One Form-A Fault Relay.
. One Form-A Supervisory Relay
. 3.0 amps ofsystem power.
. Max 30 conventional detectors in one zone.
. Auto/Manual mode setting enable.
. Each Zone can be disabled.
. Sound output can be disabled.
. Manual active sound output enabled.
. Able to report short and broken circuit
of detection zones.
. Designed with standby batteries and space provision for 1 sealed lead- acid batteries
Evacuate,Testing and disable functions.
. Remote reset and silence alarm functions
. Can conneet max 32 repeater panels by RS485 communication port
. Dimensions :14.57"(37 cm) long X 17.32"(44 cm) high X 3.94"(10cm)
. Weight: 6.6kg (without battery)

 

Specification
 
Primary AC 120VAC 50/60 Hz Power supply rating
240VAC 50/60 Hz
Power supply rating 2 Amps @ 24VDC
Maximum Battery Charging Current 0.98 Amps @ 26VDC
Initiating Device Circuits 2 Zones Alarm Zone 2
Normal Initiating Operating Voltage 23VDC, Maximum 26VDC, regulated
Normal Quiescent Current (normal status) <50mA
Alarm Current (not include the others) <150 mA
Short Circuit Initiating Current (per zone) 35mA Maximum
Maximum Initiating Resistance (per zone) 10 ohms
Initiating End-of-Line Resistor 4K7 ohms, 1/2W 5%
Standby Detector Current (per zone) 4mA maximum
Maximum Detector Count (per zone) 30 detectors
Initiating Cabling Type 18AWG Twisted Shielded pair (14 – 18 AWG)
Detector Base Impedance 430 ohms
Notification Appliance Circuits 1 NACs, Special Application
Maximum NAC Current Rating 1 Amp maximum per circuit
NAC Operating Voltage 26VDC Nominal, 30VDC Maximum
NAC End-of-line Resistor 1N4007 Diode
FAULT Relay rating 2A & 30VAC, resistive
Alarm( Auxiliary ) Relay rating 2A & 30VAC, resistive
Master alarm panel Digital & LED display
Slave alarm panel LED display only


Product range

Conventional Fire Alarm System
Addressable fire alarm system
Gas Extinguishing control system
Beam Detector
Standalone smoke detectors and combustable gas detector
4 wire smoke detectors with relay output.
2 wire Conventional smoke and heat detectors
Explosion-proof flame detector for fire alarm system




Service


1. OEM &ODM service.
2. Provide technical support and after-sale service.
3. 1 year warranty.
4. Normally 15 working days lead time.

5. Welcome sample order.